BPLAN data structure: Difference between revisions
PeterHicks (talk | contribs) m PeterHicks moved page Train Planning Data Structure to BPLAN data structure: Rename page to reflect the source system |
ThomasWood (talk | contribs) add footer record format |
||
Line 681: | Line 681: | ||
|- | |- | ||
|} | |} | ||
== Footer (PIT) record == | |||
The final record in the file which contains counts of the records in the file to ensure correct transfer and parsing. | |||
{| class="wikitable" | |||
! Type | |||
! Field | |||
! Format | |||
! Length | |||
! Values | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| PIT | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| REF | |||
|- | |||
| M | |||
| REF record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| TLD | |||
|- | |||
| M | |||
| TLD record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| LOC | |||
|- | |||
| M | |||
| LOC record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| PLT | |||
|- | |||
| M | |||
| PLT record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| NWK | |||
|- | |||
| M | |||
| NWK record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Record Type | |||
| Text | |||
| 3 | |||
| TLK | |||
|- | |||
| M | |||
| TLK record count | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|- | |||
| M | |||
| Unknown, only 0 observed. | |||
| Number | |||
| | |||
| | |||
|} | |||
{{Navtable-DataFeeds}} | {{Navtable-DataFeeds}} |
Revision as of 22:14, 17 January 2019
About
The Public Interface Format (PIF) file is a tab-separated, variable record length ASCII file containing the following sets of data:
- Reference codes as used in CIF schedule files
- Timing Loads used in train planning
- Location codes (TIPLOCs), their type (TRUST, Mandatory or Optional) and, for many records, the geographical location in Eastings/Northings
- Platform data, including platform number, length, power supply type
- Network Links between TIPLOCs, including distances
- Timing Links between TIPLOCs, including traction type, entry and exit speeds
See BPLAN Geography for the download link for this data, which is updated twice a year.
Format
The format of the file is straightforward:
- The first field on a record is a 3-character field identifying the record type
- The second field is the Action Code, which will always be 'A' - Add. The action codes 'C' and 'D' should not be seen in PIF files from the Data Feeds platform, as they are extracted as reference data, and not updates to the existing data
- The subsequent fields are tab-separated and variable-length
- A single trailer record reports the number of records of each type in the file, and indicates the end of the file
Within each record, the 'type' column indicates whether the field is part of a record key, mandatory or optional:
- P: Primary key - a field, or set of fields, that uniquely identify an entity instance
- A: Alternate key - an alternate set of fields that also uniquely identify an entity
- M: Mandatory field
- O: Optional field
Data will be provided for P, A and M fields, but not necessarily for O fields. However, the field will still be present and will be empty, i.e. the file will have two TAB characters.
Field formats
The following field formats are used:
- Date: DD-MM-YYYY HH:MM:SS
- Time: HH:MM:SS
- Duration: MM'SS
- SRT: MMM'SS
All measurements are in metric units. Times use the 24 hour clock, with midnight as 00:00:00.
A single final trailer record defines the number of records of each type in the file.
Control (PIF) record
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record type | Text | 3 | 'PIF' |
M | File version | Text | 3 | Interface specification version |
M | Source system | Text | 30 | Database from which the file was extracted |
M | TOC ID | Text | 2 | TOC identifier |
M | Timetable start date | Date | Start date of the timetable period to which this data applies | |
M | Timetable end date | Date | End date of the timetable period to which this data applies | |
M | Cycle type | Text | 1 | I - Iterative, or S - Supplemental |
M | Cycle stage | Text | 1 | 0 - Base data from Network Rail |
M | File creation date | Date | ||
M | File sequence number | Number | 4 | Unused |
Reference (REF) records
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record type | Text | 3 | REF |
M | Action code | Text | 1 | A |
P | Reference code type | Text | 3 | See below |
P | Reference code | Text | 3 | Up to 3 characters long - may be blank |
M | Description | Text | 64 | Free-format text |
The reference code types are as follows:
Code type | ID |
---|---|
Accommodation | ACC |
Bank Holidays Excepted codes | BHX |
Service brands | BRA |
Business sector | BUS |
Catering codes | CAT |
Operating characteristics codes | OPC |
Power supply type | PWR |
Reservation codes | RES |
Sleeper codes | SLE |
Train class | TCL |
Train category | TCT |
Train Operator codes | TOC |
Train status | TRS |
Train publication status | TST |
Reference code types | REF |
Network Rail zones | ZNE |
Activities at a location | ACT |
Timing Loads (TLD)
There are several point-to-point timings (Timing links) across a Network Link. When timing a train across a network link, the timing link to use depends on the train formation, as well as its entry and exit speeds.
Point-to-point timings are not needed for every train formation, as many have effectively the same timings. Timings across a network link are defined for a variety of timing loads, each applicable to a number of train formations. The timing load to use for a train may depend on its class/subclass, planned load, planned maximum speed and RA number.
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record Type | Text | 3 | TLD |
M | Action Code | Text | 1 | A |
P | Traction type | Code | 6 | Type of traction, e.g. 321, 153, 2x86, EMU |
P | Trailing Load | Code | 5 | Tonnes (up to 4 digits) plus an empty/loaded character for freight. Blank for trains with a standard trailing load |
P | Speed | Code | 3 | Maximum permitted speed for the timing load |
P | RA/Gauge | Code | 3 | First digit is the RA number, then two characters for gauge - may be blank |
M | Description | Text | 64 | Free-format text |
M | ITPS Power Type | Text | 3 | The power type as shown in ITPS |
M | ITPS Load | Text | 4 | The load as shown in ITPS |
M | Limiting Speed | Text | 3 | The limiting speed as shown in ITPS |
Location (LOC) records
Some geography items may be dated, i.e. they may have a start or end date.
NOTE: The Easting and Northing values for locations are not guaranteed to be accurate
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record type | Text | 3 | LOC |
M | Action Code | Text | 1 | A |
P | Location Code | Text | 7 | TIPLOC |
M | Location name | Text | 32 | Free text |
M | Start date | Date | ||
O | End date | Date | ||
O | OS Easting | Number | 6 | Ordnance Survey reference |
O | OS Northing | Number | 6 | Ordnance Survey reference |
M | Timing point type | T/M/O | TRUST, Mandatory or Optional | |
M | Zone | Code | Zone responsible for maintaining the record | |
O | STANOX code | Number | 5 | Station Number code |
M | Off-Network indicator | Y/N | 1 | Y if the location is off the Network Rail network, or N if it is on-network |
O | Force LPB | L/P/B/space | 1 | L if the running line code should appear in the timetable when approaching the location, P if the path should appear in the timetable when leaving the location, B for both, or space for neither |
Platforms and Sidings (PLT) records
NOTE: The Platform/Siding Length values for locations are not guaranteed to be accurate
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record Type | Text | 3 | PLT |
M | Action Code | Text | 1 | A |
P | Location code | Text | 7 | TIPLOC |
P | Platform ID | Text | 3 | UID for the platform at the location |
M | Start date | Date | ||
O | End date | Date | ||
O | Platform/Siding length | Num | 4 | Maximum usable length in metres |
M | Power supply type | Code | A valid power supply type code | |
O | DOO (Passenger) | Y/N | Driver-Only Operation allowed for passenger trains? | |
O | DOO (Non-Passenger) | Y/N | Driver-Only Operation allowed for non-passenger trains? |
Network Link (NWK) records
NOTE: The distance values for are not guaranteed to be accurate
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record Type | Text | 3 | NWK |
M | Action Code | Text | 1 | A |
P | Origin location | Text | 7 | TIPLOC |
P | Destination location | Text | 7 | TIPLOC |
P | Running line code | Code | 3 | e.g. FL, SL to distinguish parallel running lines |
O | Running line description | Text | 20 | A description for a non-standard running line code |
M | Start date | Date | ||
O | End date | Date | ||
M | Initial direction | U/D | Up/Down direction indicator - used for timetables and junction reports rather than physical line descriptions | |
O | Final direction | U/D | May differ from the initial direction, e.g. where an up link merges in to a down link | |
O | Distance | Number | 5 | Distance in metres |
O | DOO (Passenger) | Y/N | Driver-Only Operation allowed for passenger trains? | |
O | DOO (Non-Passenger) | Y/N | Driver-Only Operation allowed for non-passenger trains? | |
O | RETB | Y/N | Is Radio Electric Token Block in use at this location? | |
M | Zone | Code | Zone responsible for maintaining the record | |
M | Reversible line | B/R/N | B - Bi-directional, R - Reversible, or N - Neither | |
M | Power supply type | Code | A valid power supply type code | |
P | RA | Code | 2 | Route Availability number |
O | Maximum train length | Num | 4 | Maximum length of train that can use this network link, in metres |
Timing Link (TLK) records
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record Type | Text | 3 | TLK |
M | Action Code | Text | 1 | A |
P | Origin location | Text | 7 | TIPLOC |
P | Destination location | Text | 7 | TIPLOC |
P | Running line code | Code | 3 | e.g. FL, SL to distinguish parallel running lines |
P | Traction type | Code | 6 | Type of traction, e.g. 321, 153, 2x86, EMU |
P | Trailing Load | Code | 5 | Tonnes (up to 4 digits) plus an empty/loaded character for freight. Blank for trains with a standard trailing load |
P | Speed | Code | 3 | Maximum permitted speed for the timing load |
P | RA/Gauge | Code | 3 | First digit is the RA number, then two characters for gauge - may be blank |
P | Entry speed | Number | 3 | 0 for starting or -1 for passing at maximum appropriate speed |
P | Exit speed | Number | 3 | 0 for stopping or -1 for passing at maximum appropriate speed |
P | Start date | Date | ||
O | End date | Date | ||
M | Sectional Running Time | SRT | mmm'ss | |
O | Description | Text | 64 |
The final record in the file which contains counts of the records in the file to ensure correct transfer and parsing.
Type | Field | Format | Length | Values |
---|---|---|---|---|
M | Record Type | Text | 3 | PIT |
M | Record Type | Text | 3 | REF |
M | REF record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Record Type | Text | 3 | TLD |
M | TLD record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Record Type | Text | 3 | LOC |
M | LOC record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Record Type | Text | 3 | PLT |
M | PLT record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Record Type | Text | 3 | NWK |
M | NWK record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Record Type | Text | 3 | TLK |
M | TLK record count | Number | ||
M | Unknown, only 0 observed. | Number | ||
M | Unknown, only 0 observed. | Number |
Network Rail Open Data Feeds | |
---|---|
Data Feeds | About the Feeds • Account States • Durable Subscriptions • Example Code ( PHP / C# / Java / Ruby / Node.js) • Advanced Uses • FAQ • Release Notes |
RTPPM | RTPPM Feed |
Train Movements | Train Movements Feed • Train Activation • Train Cancellation • Train Movement • Train Reinstatement • Change of Origin • Change of Identity • Change of Location • TSPEED Field • Planned Cancellations • Cancellation Codes |
TD | TD Feed • C-Class Messages • S-Class Messages • Train Describers • TD Berths |
VSTP | VSTP Feed |
TSR | TSR Feed • Route Codes |
SCHEDULE | SCHEDULE Feed • TIPLOC Records • Schedule and Location Records • Association Records • CIF Codes • How Scheduling Works • Allowances |
Reference Data | Reference Data Feed • TOC Codes • CIF Codes • Delay Attribution Codes • Identifying Locations (STANOX, TIPLOC, NLC and 3-Alpha Codes) • STANOX Geographical Areas • Train Planning data (BPLAN) |