== Overview ==
An activation message is produced when a ''train entity'' is created from a ''schedule entity'' by the TRUST system.  The ''train entity'' refers to a single run of a train on a specific day whereas the ''schedule entity'' is potentially valid for several months at a time.  Within TRUST, this process is known as ''Train Call''.


In IT terms, an activation message is produced when a 'train entity' is created from a 'schedule entity'.  The train entity refers to a single run of a train, starting on one day whereas the schedule entity is potentially valid for several months at a timeWithin TRUST, this process is known as 'Train Call'
Most trains are called automatically (''auto-call'') some time before the train is due to run.  See the [[Train_Call_Window|Train Call Window]] page for the current window sizes.


For most trains, there is no corresponding business event which triggers an activation, which happens automatically (auto-call) before the train is due to run.
The TRUST mainframe runs an internal process every 30 seconds throughout the day, causing potentially two lots of automatic train activation messages to be received every minute.


The exception to this is for schedules which are "Runs as required", or "Runs to terminals/yards as required" - flagged with Q or Y in the schedule.  By default, it is assumed that the train will not run unless the train operator decides that it will, and submits a message to the TRUST system.  This will then cause the schedule to be activated for that day, and the activation process is known as 'manual call'.
Schedules which is ''Runs as required'', or ''Runs to terminals/yards as required'' (i.e. those with Q, Y or both in the schedule characteristics) are called manually - the train operator will submit a message to the TRUST system and this will then cause the schedule to be activated for that day (a process is known as ''manual call''.).  Other trains may be required to be called manually depending on other characteristics.


Train activations are usually received either one or two hours before the train is due to run, but these trains may be manually called earlier if some details of the train are due to change.
Any train may be manually called some hours in advance if the train is to be cancelled (e.g. a cancellation of a 6pm service which is decided at 8am will result in an auto-call train being manually called and then cancelled).


The activation message includes the schedule UID, schedule STP Indicator, and a 10-character ID (unique only within a calendar month) which is seen in all further message for a the train. 
= Data structure =


== Data structure ==
<pre>
{
    "header": {
        "msg_type": "0001",
        "source_dev_id": "",
        "user_id": "",
        "original_data_source": "TSIA",
        "msg_queue_timestamp": "1511528234000",
        "source_system_id": "TRUST"
    },
    "body": {
        "schedule_source": "C",
        "train_file_address": null,
        "schedule_end_date": "2017-12-08",
        "train_id": "775F25MP24",
        "tp_origin_timestamp": "2017-11-24",
        "creation_timestamp": "1511528234000",
        "tp_origin_stanox": "",
        "origin_dep_timestamp": "1511535420000",
        "train_service_code": "25470001",
        "toc_id": "25",
        "d1266_record_number": "00000",
        "train_call_type": "AUTOMATIC",
        "train_uid": "C21373",
        "train_call_mode": "NORMAL",
        "schedule_type": "O",
        "sched_origin_stanox": "77301",
        "schedule_wtt_id": "5F25M",
        "schedule_start_date": "2016-12-12"
    }
}
</pre>


=== Header ===
== Header ==


{| class='wikitable'
{| class='wikitable'
Line 20: Line 51:
|-
|-
|msg_type
|msg_type
|Set to '0001' for an activation message
|'0001' for an activation message
|-
|-
|source_dev_id
|source_dev_id
|Always blank for an activation message
|-
|user_id
|Always blank for an activation message
|Always blank for an activation message
|-
|-
|source_system_id
|source_system_id
|Set to "TRUST" for an activation message
|"TRUST" for an activation message
|-
|-
|original_data_source
|original_data_source
|Set to "TSIA" for an activation message
|"TSIA" for an activation message
|-
|msg_queue_timestamp
|
|}
|}


=== Body ===
== Body ==


{| class='wikitable'
{| class='wikitable'
Line 38: Line 75:
!Description
!Description
|-
|-
|train_id
|schedule_source
|Set to the 10-character unique identity for this train, and will appear in other TRUST message types
|Set to ''C'' for schedules from CIF/ITPS, or ''V'' for schedules from VSTP/TOPS
|-
|-
|creation_timestamp
|train_file_address
|The time, in milliseconds, when the train was originally created in TRUST
|The TOPS train file address, if applicable
|-
|-
|tp_origin_timestamp
|schedule_end_date
|The date, in YYYY-MM-DD format, the train runs.  For trains activated before midnight that run after midnight, this date will be "tomorrow's" date
|The end date of the schedule
|-
|-
|train_uid
|train_id
|The UID of the schedule being activated - either a letter and five numbers, or a space and five numbers for VSTP trains
|The 10-character identity for this train. If the schedule is due to run over multiple months, the identifier can be used on the same date every month (12th Feb, 12th March, etc).
 
This is used in other TRUST messages to identify the train. The train activation message links the ''train_id'' with a particular schedule.  ''train_id'' is of the format ''AABBBBCDEE'' where:
 
* ''AA'' is the first two digits of the origin STANOX, and represents the area where the train starts
* ''BBBB'' is the signalling ID (headcode) used within the data feeds to represent the train
* ''C'' is the TSPEED value of the train (see [[TSPEED | valid TSPEED values]]) - note: this does not refer to the actual speed (velocity) of the train
* ''D'' is the [[Call Code]] of the train - a letter or number based on the departure time from the origin
* ''EE'' is the day of the month on which the train originated
|-
|-
|sched_origin_stanox
|tp_origin_timestamp
|STANOX of the originating locationMay not be nil
|The date, in YYYY-MM-DD format, that the train runs.  For trains activated before midnight that run after midnight, this date will be tomorrow's date.
'''Note:''' there is currently a problem with the ''tp_origin_timestamp'' field due to the truncation of the timestampThis only occurs during daylight savings for trains which start their journey between 0001 and 0200 the next day.  To work around this problem, use the date in the ''origin_dep_timestamp'' field.
|-
|-
|sched_start_date
|creation_timestamp
|The start date of the schedule
|The timestamp (in ''milliseconds'' since the UNIX epoch) when the train was originally created in TRUST
|-
|-
|schedule_end_date
|tp_origin_stanox
|The end date of the schedule
|The [[STANOX]] code of the origin of the train
If the train is due to start from a location other than the scheduled origin (i.e. it is part-cancelled), this will be the STANOX of the location at which the train starts.  Otherwise this field will be empty and you should refer to the 'sched_origin_stanox' field.  If this field is populated, it will be typically be in response to a VAR issued through VSTP or [[SCHEDULE]].
|-
|-
|schedule_source
|origin_dep_timestamp
|Set to 'C' for schedules from CIF/ITPS, or 'V' for schedules from VSTP/TOPS
|The WTT time of departure from the originating location.  A UNIX timestamp in milliseconds since the UNIX epoch, in UTC.
|-
|-
|schedule_type
|train_service_code
|Either C (Cancellation), N (New STP), O (STP Overlay) or P (LTP)
|Train service code as per schedule
|-
|-
|sched_wtt_id
|toc_id
|The headcode and TSPEED of the train (either '1', '2', '3', '4', 'C', 'M', 'N' or 'O')
|Operating company ID as per [[TOC Codes]]
|-
|-
|d1266_record_number
|d1266_record_number
|Either '00000' for a CIF/ITPS schedule, or the TOPS unique ID of the schedule
|Either ''00000'' for a CIF/ITPS schedule, or the TOPS unique ID of the schedule.  This will always be ''00000'' for train activation messages, as TRUST generates the train activation message as part of the train call process, then sends the train to TOPS if appropriate, where it is assigned a D1266 record number
|-
|-
|tp_origin_stanox
|train_call_type
|If the train is due to start from a location other than the origin (i.e. it is part-cancelled), the STANOX of the location at which the train starts, otherwise the STANOX of the scheduled origin location.
|Either ''AUTOMATIC'' for auto-called trains, or ''MANUAL'' for manual-called trains
 
If this field is populated, it will be typically be in response to a VAR issued through VSTP or SCHEDULE.
|-
|-
|origin_dep_timestamp
|train_uid
|The estimated WTT time of departure from the originating location
|The unique ID of the schedule being activated - either a letter and five numbers, or a space and five numbers for VSTP trains
|-
|-
|train_call_type
|train_call_mode
|Either 'AUTOMATIC' for auto-called trains, or 'MANUAL' for manual-called trains
|Always set to ''NORMAL''.  Historically, this could contain ''OVERNIGHT'' if the train is called as part of an overnight batch process to activate peak period trains early, but this no longer happens
|-
|-
|train_call_mode
|schedule_type
|Set to 'NORMAL' for a train called normally, or 'OVERNIGHT' if the train is called as part of an overnight batch process to activate peak period trains early
|Either ''C'' (Cancellation), ''N'' (New STP), ''O'' (STP Overlay) or ''P'' (Permanent i.e. as per the WTT/LTP) '''Note:''' There is a bug that causes this field to be populated incorrectly. The value ''O'' should be ''P'' and ''P'' should be ''O''.
|-
|-
|toc_id
|sched_origin_stanox
|Operating company ID as per [[TOC_Codes]]
|[[STANOX]] code for the originating location in the schedule
|-
|-
|train_service_code
|schedule_wtt_id
|Train service code as per schedule
|The signalling ID (headcode) and [[TSPEED | speed class]] of the train
|-
|-
|train_file_address
|schedule_start_date
|The TOPS train file address, if applicable
|The start date of the schedule
|}
|}
= Linking with Schedule Data =
The train activation message is the only message type which directly links a signalling ID to a schedule.  There are ways to infer this relationship using other data, but it is much more difficult. 
An individual schedule is identified by the unique schedule identifier (''train_uid''), the schedule start date (''schedule_start_date'') and the schedule type (''schedule_type'', or STP Indicator in CIF).
See the [[LTP_and_STP_Processes | LTP and STP Process]] page for more details.
{{Navtable-DataFeeds}}
[[Category:Train Movement Data]]
[[Category:Train Activation Messages]]

Latest revision as of 15:17, 14 February 2024

An activation message is produced when a train entity is created from a schedule entity by the TRUST system. The train entity refers to a single run of a train on a specific day whereas the schedule entity is potentially valid for several months at a time. Within TRUST, this process is known as Train Call.

Most trains are called automatically (auto-call) some time before the train is due to run. See the Train Call Window page for the current window sizes.

The TRUST mainframe runs an internal process every 30 seconds throughout the day, causing potentially two lots of automatic train activation messages to be received every minute.

Schedules which is Runs as required, or Runs to terminals/yards as required (i.e. those with Q, Y or both in the schedule characteristics) are called manually - the train operator will submit a message to the TRUST system and this will then cause the schedule to be activated for that day (a process is known as manual call.). Other trains may be required to be called manually depending on other characteristics.

Any train may be manually called some hours in advance if the train is to be cancelled (e.g. a cancellation of a 6pm service which is decided at 8am will result in an auto-call train being manually called and then cancelled).

Data structure

{
    "header": {
        "msg_type": "0001",
        "source_dev_id": "",
        "user_id": "",
        "original_data_source": "TSIA",
        "msg_queue_timestamp": "1511528234000",
        "source_system_id": "TRUST"
    },
    "body": {
        "schedule_source": "C",
        "train_file_address": null,
        "schedule_end_date": "2017-12-08",
        "train_id": "775F25MP24",
        "tp_origin_timestamp": "2017-11-24",
        "creation_timestamp": "1511528234000",
        "tp_origin_stanox": "",
        "origin_dep_timestamp": "1511535420000",
        "train_service_code": "25470001",
        "toc_id": "25",
        "d1266_record_number": "00000",
        "train_call_type": "AUTOMATIC",
        "train_uid": "C21373",
        "train_call_mode": "NORMAL",
        "schedule_type": "O",
        "sched_origin_stanox": "77301",
        "schedule_wtt_id": "5F25M",
        "schedule_start_date": "2016-12-12"
    }
}

Header

Field Description
msg_type '0001' for an activation message
source_dev_id Always blank for an activation message
user_id Always blank for an activation message
source_system_id "TRUST" for an activation message
original_data_source "TSIA" for an activation message
msg_queue_timestamp

Body

Field Description
schedule_source Set to C for schedules from CIF/ITPS, or V for schedules from VSTP/TOPS
train_file_address The TOPS train file address, if applicable
schedule_end_date The end date of the schedule
train_id The 10-character identity for this train. If the schedule is due to run over multiple months, the identifier can be used on the same date every month (12th Feb, 12th March, etc).

This is used in other TRUST messages to identify the train. The train activation message links the train_id with a particular schedule. train_id is of the format AABBBBCDEE where:

  • AA is the first two digits of the origin STANOX, and represents the area where the train starts
  • BBBB is the signalling ID (headcode) used within the data feeds to represent the train
  • C is the TSPEED value of the train (see valid TSPEED values) - note: this does not refer to the actual speed (velocity) of the train
  • D is the Call Code of the train - a letter or number based on the departure time from the origin
  • EE is the day of the month on which the train originated
tp_origin_timestamp The date, in YYYY-MM-DD format, that the train runs. For trains activated before midnight that run after midnight, this date will be tomorrow's date.

Note: there is currently a problem with the tp_origin_timestamp field due to the truncation of the timestamp. This only occurs during daylight savings for trains which start their journey between 0001 and 0200 the next day. To work around this problem, use the date in the origin_dep_timestamp field.

creation_timestamp The timestamp (in milliseconds since the UNIX epoch) when the train was originally created in TRUST
tp_origin_stanox The STANOX code of the origin of the train

If the train is due to start from a location other than the scheduled origin (i.e. it is part-cancelled), this will be the STANOX of the location at which the train starts. Otherwise this field will be empty and you should refer to the 'sched_origin_stanox' field. If this field is populated, it will be typically be in response to a VAR issued through VSTP or SCHEDULE.

origin_dep_timestamp The WTT time of departure from the originating location. A UNIX timestamp in milliseconds since the UNIX epoch, in UTC.
train_service_code Train service code as per schedule
toc_id Operating company ID as per TOC Codes
d1266_record_number Either 00000 for a CIF/ITPS schedule, or the TOPS unique ID of the schedule. This will always be 00000 for train activation messages, as TRUST generates the train activation message as part of the train call process, then sends the train to TOPS if appropriate, where it is assigned a D1266 record number
train_call_type Either AUTOMATIC for auto-called trains, or MANUAL for manual-called trains
train_uid The unique ID of the schedule being activated - either a letter and five numbers, or a space and five numbers for VSTP trains
train_call_mode Always set to NORMAL. Historically, this could contain OVERNIGHT if the train is called as part of an overnight batch process to activate peak period trains early, but this no longer happens
schedule_type Either C (Cancellation), N (New STP), O (STP Overlay) or P (Permanent i.e. as per the WTT/LTP) Note: There is a bug that causes this field to be populated incorrectly. The value O should be P and P should be O.
sched_origin_stanox STANOX code for the originating location in the schedule
schedule_wtt_id The signalling ID (headcode) and speed class of the train
schedule_start_date The start date of the schedule

Linking with Schedule Data

The train activation message is the only message type which directly links a signalling ID to a schedule. There are ways to infer this relationship using other data, but it is much more difficult.

An individual schedule is identified by the unique schedule identifier (train_uid), the schedule start date (schedule_start_date) and the schedule type (schedule_type, or STP Indicator in CIF).

See the LTP and STP Process page for more details.


Network Rail Open Data Feeds
Data Feeds About the Feeds Account States Durable Subscriptions Example Code ( PHP / C# / Java / Ruby / Node.js) • Advanced UsesFAQ Release Notes
RTPPM RTPPM Feed
Train Movements Train Movements Feed Train Activation Train Cancellation Train Movement Train Reinstatement Change of Origin Change of Identity Change of Location TSPEED Field Planned Cancellations Cancellation Codes
TD TD Feed C-Class Messages S-Class Messages Train Describers TD Berths
VSTP VSTP Feed
TSR TSR Feed Route Codes
SCHEDULE SCHEDULE Feed TIPLOC Records Schedule and Location Records Association Records CIF Codes How Scheduling Works Allowances
Reference Data Reference Data Feed TOC Codes CIF Codes Delay Attribution Codes Identifying Locations (STANOX, TIPLOC, NLC and 3-Alpha Codes) STANOX Geographical Areas Train Planning data (BPLAN)