The CIF 'TD' record instructs that a system should delete an existing TIPLOC in to its local database, if it has one.

Record Format

TDMLCHSTR                                                                       

Record Fields

Field Format Length Example Value Comments
Record Identity String 2 TD Constant value 'TD'
TIPLOC code String 7 MLCHSTR Timing Point Location code
Spare String 71 (empty space)


CIF
CIF HD (Header) • ZZ (End of File)
TIPLOC TI (TIPLOC Insert) TA (TIPLOC Amend) TD (TIPLOC Delete)